Instructions for assembly and use MULTICAL® 601 www.kamstrup.com

Strona 2 - 1.1 MID labelling

6.2 Main voltage modules Modules belong to the safety class ll, and are connected with a double-wire conductor (without grounding) through the calcula

Strona 3 - 601 & ULTRAFLOW

8. Electric connection The polarity of T1, T2 and T3 temperature sensors is not important. When connecting ULTRAFLOW® and electronic sensor units, use

Strona 4 - 1. General information

NOTE! If data reading is to be compatible with MULTICAL® 66-CDE, a top module 67-06 needs to be used in MULTICAL® 601. Impulse inputs can be used for

Strona 5

9.4 Analogue output Type 67-00-23, see Assembly guide 5512-369 (DK-GB-DE). 9.5 Lon Works Type 67-00-24, see Assembly manual 5512-396 (DK) or 55-2-403

Strona 6 - 3. Information ‘E’ codes

Type 67-07: RTC + M-Bus An M-Bus can be connected into a star, ring, or bus line. According to M-Bus Master supply and cable length/diameter, up to

Strona 9 - 6. Power supply

1.1 MID labelling Standard conditions of operation/measuring rates: Meter θ: 10°C…180°C ∆Θ: 3K…170K A pair of resistance temperature sensors θ: 1

Strona 10 - 7. Function test

MULTICAL® 601 & ULTRAFLOW® English Kamstrup A/S Industrivej 28, Stilling, DK-8660 Skanderborg PHONE NO.: +45

Strona 11 - 9. Insert modules

1. General information Before installing the power meter, study this guide carefully. In case the meter is not properly installed, the Kamstrup Compa

Strona 12

Temperature sensors must be inserted all the way to the bottom of the containers. If a short period of response is required, a non-setting heat conduc

Strona 13

3. Information ‘E’ codes MULTICAL® 601 continuously monitors a range of important functions. In case of serious damage in the measuring system or ins

Strona 14

To prevent cavitations, the ULTRAFLOW® operating pressure must be min. 1.5 bar for qp min. 2.5 bar for qs (4.5 bar for DN80). This requirement is vali

Strona 15

Assembly example: MULTICAL® can be mounted in two positions using angle bracket. The 3026-252 angle bracket needs to be ordered separ

Strona 16

5.2 Separate assembly on the wall The bracket for wall mounting enables you to mount MULTICAL® 601 directly onto a straight wall. Use the brac